Carrier furnace status-code reference

TG-GFC80-02 provides a bounded numbered-status reference. Its 58CVA / 58CVX nomenclature does not extend this table to all Carrier furnaces. Identify the full guide and operating context before selecting a pattern.

FURNACE REFERENCE · SOURCE PILOT

Start with your Carrier furnace paperwork

Begin with the manual-scoped TG-GFC80-02 pilot below. The two newer owner manuals are general references without code tables; they are not evidence that this older guide applies to those product families.

CARRIER / FURNACE / MANUAL-SCOPED PILOT

TG-GFC80-02 · 58CVA / 58CVX

This guide’s nomenclature identifies 58CVA / 58CVX furnaces. It does not establish an exact installed model, series or control match. Do not use it for 59SC6, 59SP6, another Carrier family or Goodman equipment based on a similar pattern. Identify the full manual number in paperwork you already have; do not open equipment to find it.

Open TG-GFC80-02 · family nomenclature, page 2 → Edition 05/18; source accessed 2026-11-15. The two owner manuals below are separate sources and do not establish this guide’s applicability.

Seventeen numbered headings from Service/Status Code Instructions, printed / PDF pages 6–8. First digit: short flashes; second digit: long flashes of the amber status LED. Continuous and rapid states are outside this pilot. No flash durations are inferred.

Operating context matters: the separate component-test table gives code 11 a different meaning. This lookup covers the numbered service/status table only. It does not retrieve history or run a test. “No previous code” does not establish that equipment is operating safely or without a fault.

  1. Code 11 · 1 short flash, then 1 long flash

    NO PREVIOUS CODE

    Manufacturer table heading only, not a confirmed cause or repair instruction. Numbered service/status context only; exact unit/control applicability remains unconfirmed.

    Manufacturer-sourced; not reviewed by a qualified technician.

    TG-GFC80-02 · edition 05/18 · printed / PDF page 6 · SERVICE/STATUS CODE INSTRUCTIONS

    Return to Carrier lookup → · Record observations for service →

  2. Code 12 · 1 short flash, then 2 long flashes

    BLOWER ON AFTER POWER UP

    Manufacturer table heading only, not a confirmed cause or repair instruction. Numbered service/status context only; exact unit/control applicability remains unconfirmed.

    Manufacturer-sourced; not reviewed by a qualified technician.

    TG-GFC80-02 · edition 05/18 · printed / PDF page 6 · SERVICE/STATUS CODE INSTRUCTIONS

    Return to Carrier lookup → · Record observations for service →

  3. Code 13 · 1 short flash, then 3 long flashes

    LIMIT CIRCUIT LOCKOUT

    Manufacturer table heading only, not a confirmed cause or repair instruction. Numbered service/status context only; exact unit/control applicability remains unconfirmed.

    Manufacturer-sourced; not reviewed by a qualified technician.

    TG-GFC80-02 · edition 05/18 · printed / PDF page 6 · SERVICE/STATUS CODE INSTRUCTIONS

    Return to Carrier lookup → · Record observations for service →

  4. Code 14 · 1 short flash, then 4 long flashes

    IGNITION LOCKOUT

    Manufacturer table heading only, not a confirmed cause or repair instruction. Numbered service/status context only; exact unit/control applicability remains unconfirmed.

    Manufacturer-sourced; not reviewed by a qualified technician.

    TG-GFC80-02 · edition 05/18 · printed / PDF page 6 · SERVICE/STATUS CODE INSTRUCTIONS

    Return to Carrier lookup → · Record observations for service →

  5. Code 15 · 1 short flash, then 5 long flashes

    BLOWER MOTOR LOCKOUT

    Manufacturer table heading only, not a confirmed cause or repair instruction. Numbered service/status context only; exact unit/control applicability remains unconfirmed.

    Manufacturer-sourced; not reviewed by a qualified technician.

    TG-GFC80-02 · edition 05/18 · printed / PDF page 7 · SERVICE/STATUS CODE INSTRUCTIONS

    Return to Carrier lookup → · Record observations for service →

  6. Code 21 · 2 short flashes, then 1 long flash

    GAS HEATING LOCKOUT

    Manufacturer table heading only, not a confirmed cause or repair instruction. Numbered service/status context only; exact unit/control applicability remains unconfirmed.

    Manufacturer-sourced; not reviewed by a qualified technician.

    TG-GFC80-02 · edition 05/18 · printed / PDF page 7 · SERVICE/STATUS CODE INSTRUCTIONS

    Return to Carrier lookup → · Record observations for service →

  7. Code 22 · 2 short flashes, then 2 long flashes

    ABNORMAL FLAME-PROVING SIGNAL

    Manufacturer table heading only, not a confirmed cause or repair instruction. Numbered service/status context only; exact unit/control applicability remains unconfirmed.

    Manufacturer-sourced; not reviewed by a qualified technician.

    TG-GFC80-02 · edition 05/18 · printed / PDF page 7 · SERVICE/STATUS CODE INSTRUCTIONS

    Return to Carrier lookup → · Record observations for service →

  8. Code 23 · 2 short flashes, then 3 long flashes

    PRESSURE SWITCH DID NOT OPEN

    Manufacturer table heading only, not a confirmed cause or repair instruction. Numbered service/status context only; exact unit/control applicability remains unconfirmed.

    Manufacturer-sourced; not reviewed by a qualified technician.

    TG-GFC80-02 · edition 05/18 · printed / PDF page 7 · SERVICE/STATUS CODE INSTRUCTIONS

    Return to Carrier lookup → · Record observations for service →

  9. Code 24 · 2 short flashes, then 4 long flashes

    SECONDARY VOLTAGE FUSE IS OPEN

    Manufacturer table heading only, not a confirmed cause or repair instruction. Numbered service/status context only; exact unit/control applicability remains unconfirmed.

    Manufacturer-sourced; not reviewed by a qualified technician.

    TG-GFC80-02 · edition 05/18 · printed / PDF page 7 · SERVICE/STATUS CODE INSTRUCTIONS

    Return to Carrier lookup → · Record observations for service →

  10. Code 25 · 2 short flashes, then 5 long flashes

    MODEL SELECTION OR SETUP ERROR

    Manufacturer table heading only, not a confirmed cause or repair instruction. Numbered service/status context only; exact unit/control applicability remains unconfirmed.

    Manufacturer-sourced; not reviewed by a qualified technician.

    TG-GFC80-02 · edition 05/18 · printed / PDF page 7 · SERVICE/STATUS CODE INSTRUCTIONS

    Return to Carrier lookup → · Record observations for service →

  11. Code 31 · 3 short flashes, then 1 long flash

    HIGH-HEAT PRESSURE SWITCH OR RELAY DID NOT CLOSE OR REOPENED

    Manufacturer table heading only, not a confirmed cause or repair instruction. Numbered service/status context only; exact unit/control applicability remains unconfirmed.

    Manufacturer-sourced; not reviewed by a qualified technician.

    TG-GFC80-02 · edition 05/18 · printed / PDF page 7 · SERVICE/STATUS CODE INSTRUCTIONS

    Return to Carrier lookup → · Record observations for service →

  12. Code 32 · 3 short flashes, then 2 long flashes

    LOW-HEAT PRESSURE SWITCH DID NOT CLOSE OR REOPENED

    Manufacturer table heading only, not a confirmed cause or repair instruction. Numbered service/status context only; exact unit/control applicability remains unconfirmed.

    Manufacturer-sourced; not reviewed by a qualified technician.

    TG-GFC80-02 · edition 05/18 · printed / PDF page 7 · SERVICE/STATUS CODE INSTRUCTIONS

    Return to Carrier lookup → · Record observations for service →

  13. Code 33 · 3 short flashes, then 3 long flashes

    LIMIT CIRCUIT FAULT

    Manufacturer table heading only, not a confirmed cause or repair instruction. Numbered service/status context only; exact unit/control applicability remains unconfirmed.

    Manufacturer-sourced; not reviewed by a qualified technician.

    TG-GFC80-02 · edition 05/18 · printed / PDF page 7 · SERVICE/STATUS CODE INSTRUCTIONS

    Return to Carrier lookup → · Record observations for service →

  14. Code 34 · 3 short flashes, then 4 long flashes

    IGNITION PROVING FAILURE

    Manufacturer table heading only, not a confirmed cause or repair instruction. Numbered service/status context only; exact unit/control applicability remains unconfirmed.

    Manufacturer-sourced; not reviewed by a qualified technician.

    TG-GFC80-02 · edition 05/18 · printed / PDF page 8 · SERVICE/STATUS CODE INSTRUCTIONS

    Return to Carrier lookup → · Record observations for service →

  15. Code 41 · 4 short flashes, then 1 long flash

    BLOWER MOTOR FAULT

    Manufacturer table heading only, not a confirmed cause or repair instruction. Numbered service/status context only; exact unit/control applicability remains unconfirmed.

    Manufacturer-sourced; not reviewed by a qualified technician.

    TG-GFC80-02 · edition 05/18 · printed / PDF page 8 · SERVICE/STATUS CODE INSTRUCTIONS

    Return to Carrier lookup → · Record observations for service →

  16. Code 43 · 4 short flashes, then 3 long flashes

    LOW-HEAT PRESSURE SWITCH OPEN WHILE HIGH-HEAT PRESSURE SWITCH IS CLOSED

    Manufacturer table heading only, not a confirmed cause or repair instruction. Numbered service/status context only; exact unit/control applicability remains unconfirmed.

    Manufacturer-sourced; not reviewed by a qualified technician.

    TG-GFC80-02 · edition 05/18 · printed / PDF page 8 · SERVICE/STATUS CODE INSTRUCTIONS

    Return to Carrier lookup → · Record observations for service →

  17. Code 45 · 4 short flashes, then 5 long flashes

    CONTROL CIRCUITRY LOCKOUT

    Manufacturer table heading only, not a confirmed cause or repair instruction. Numbered service/status context only; exact unit/control applicability remains unconfirmed.

    Manufacturer-sourced; not reviewed by a qualified technician.

    TG-GFC80-02 · edition 05/18 · printed / PDF page 8 · SERVICE/STATUS CODE INSTRUCTIONS

    Return to Carrier lookup → · Record observations for service →

If the furnace is not heating, documentation is uncertain or a pattern is unlisted, contact a qualified HVAC professional. Do not open panels, change switches, bypass safeties, reset equipment or test gas/electrical parts using this reference. If you suspect gas leakage or a carbon monoxide hazard, leave the area and contact emergency services or your utility from a safe location.

Prepare observations without a code →
OWNER REFERENCE · NO CODE TABLE

OM9GFRC-02

CONDENSING GAS FURNACE — OWNER’S MANUAL

Edition: 04/20. Linked product family: 59SP6; exact applicability unconfirmed.

Printed / PDF pages 10–11: service-call observations and status-display reference. Page 12: document identifier and edition.

Open official owner manual →

Source accessed 2026-11-15. Source inspection is not diagnostic verification.

OWNER REFERENCE · NO CODE TABLE

90GSFRN-C-03OM

CONDENSING, 90+% AFUE GAS FURNACE — OWNER’S MANUAL

Edition: 03/22. Linked product family: 59SC6; exact applicability unconfirmed.

Printed / PDF pages 10–11: service-call observations and status-display reference. Page 12: document identifier and edition.

Open official owner manual →

Source accessed 2026-11-15. Source inspection is not diagnostic verification.

Have accessible installation paperwork? Record its full document number, revision and furnace model for a service professional. Do not remove equipment panels to find a code chart or change switches, wiring or gas controls.

Carrier furnace not heating?

Record what you observe and download service notes. No code is required.

Prepare furnace-not-heating observations →

The observation guide is general editorial guidance, not a Carrier-specific diagnosis. If you smell gas, leave the building and contact your gas supplier or emergency services from a safe location. Equipment diagnosis and repairs belong to a qualified professional.