Three blinks on a standard Rheem furnace means a limit or related safety switch is open, often because of overheating or restricted airflow.
Easy
A three-blink code indicates that a limit switch is open. The furnace has detected an overheating condition or another open safety circuit and has interrupted burner operation.
Burners shut off while the blower continues running; furnace cycles on and off; reduced airflow; unusually hot cabinet or supply air; heating may resume after the furnace cools and then stop again.
Dirty air filter; blocked return air; too many closed supply registers; blower motor or capacitor problem; incorrect blower speed; dirty evaporator coil; restricted ductwork; open high-limit or rollout switch; combustion problem.
1. Turn off furnace power. 2. Check and replace a dirty air filter with the correct size and type. 3. Open supply registers and make sure return-air grilles are not blocked. 4. Look for signs of overheating, scorching, soot, or a tripped manual-reset rollout switch without resetting it. 5. Restore power once and observe operation. 6. A qualified technician should verify temperature rise, blower performance, limit-switch operation, duct restrictions, and combustion safety if the code returns.
High-limit switch; rollout switches; blower motor and capacitor; air filter; evaporator coil; duct system; integrated furnace control.
Yes if the code returns after checking the filter and airflow, or immediately if there is soot, scorching, a burning smell, or a tripped rollout switch.
Do not bypass or repeatedly reset a limit or rollout switch. A rollout fault can indicate a serious combustion or venting hazard.