Lennox Error Code E154 indicates Refrigerant leak detector sensor #1 communication lost or invalid sensor DIP switch configuration. Start by checking the most common and safe items identified in the troubleshooting section. If the code returns after those checks, professional diagnosis is recommended.
Easy
Refrigerant leak detector sensor #1 communication lost or invalid sensor DIP switch configuration
Unknown
Issue with wiring harness connecting sensor #1 to control board or incorrect low GWP DIP switch settings
Check wiring harness and connector for sensor #1; check sensor for damage or obstruction; check low GWP dip switch settings; fault clears when communications restored (blower may latch for 5 minutes)
Sensor #1 harness and connector, control board, DIP switches
Call an HVAC technician if the error persists after completing the recommended basic troubleshooting steps or if the system repeatedly locks out.
Disconnect power before inspecting the equipment. Never bypass safety devices or operate the system if you suspect unsafe conditions.