Bryant error code 41 means the variable-speed blower did not reach operating speed or communicate correctly with the furnace control.
Advanced
Error code 41 means the variable-speed blower failed to reach the required speed or failed to communicate with the furnace control within the allowed time.
Little or no airflow; blower does not start; furnace may shut burners off; blower starts intermittently; motor may surge or stop; code 41 displayed; repeated faults may lead to blower motor lockout.
Loss of power to blower motor; loose or damaged motor harness; failed ECM motor or control module; blocked or jammed blower wheel; water damage; incorrect wiring; failed furnace control; excessive static pressure.
1. Turn off furnace power before removing the blower panel. 2. Replace a dirty filter and open supply and return vents. 3. Look for visible water near the blower compartment. 4. Listen for humming, repeated starting, scraping, or no blower operation. 5. Do not probe ECM motor wiring or spin the wheel with power on. 6. A technician should verify line voltage, control communication, wiring harnesses, motor RPM, static pressure, wheel condition, and the ECM module.
Variable-speed ECM blower motor; motor control module; blower wheel; wiring harness; integrated furnace control; filter and duct system.
Call a technician if the blower does not run, airflow is weak after replacing the filter, the motor makes abnormal noises, or code 41 returns.
The blower circuit includes line voltage and sensitive electronic controls. Disconnect power and leave motor testing or replacement to a qualified professional.